Foffset¶
SCPI Commands
CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:FOFFset:EDRate
CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:FOFFset:BRATe
- class Foffset[source]
Foffset commands group definition. 11 total commands, 3 Sub-groups, 2 group commands
- get_brate() → int[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:FOFFset:BRATe value: int or bool = driver.configure.rfSettings.dtx.sing.foffset.get_brate()
- Specify the constant frequency offset to be added to the center frequency.
INTRO_CMD_HELP: Refer also to the following commands:
RF tests:
Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE connection tests (normal mode) :
Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE test mode:
Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.
- return
freq_offset: numeric | ON | OFF Range: -250 kHz to 250 kHz Additional ON/OFF enables/disables constant frequency offset
- get_edrate() → int[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:FOFFset:EDRate value: int or bool = driver.configure.rfSettings.dtx.sing.foffset.get_edrate()
- Specify the constant frequency offset to be added to the center frequency.
INTRO_CMD_HELP: Refer also to the following commands:
RF tests:
Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE connection tests (normal mode) :
Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE test mode:
Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.
- return
freq_offset: numeric | ON | OFF Range: -250 kHz to 250 kHz Additional ON/OFF enables/disables constant frequency offset
- set_brate(freq_offset: int) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:FOFFset:BRATe driver.configure.rfSettings.dtx.sing.foffset.set_brate(freq_offset = 1)
- Specify the constant frequency offset to be added to the center frequency.
INTRO_CMD_HELP: Refer also to the following commands:
RF tests:
Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE connection tests (normal mode) :
Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE test mode:
Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.
- param freq_offset
numeric | ON | OFF Range: -250 kHz to 250 kHz Additional ON/OFF enables/disables constant frequency offset
- set_edrate(freq_offset: int) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:FOFFset:EDRate driver.configure.rfSettings.dtx.sing.foffset.set_edrate(freq_offset = 1)
- Specify the constant frequency offset to be added to the center frequency.
INTRO_CMD_HELP: Refer also to the following commands:
RF tests:
Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE connection tests (normal mode) :
Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.
INTRO_CMD_HELP: Refer also to the following commands:
LE test mode:
Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.
- param freq_offset
numeric | ON | OFF Range: -250 kHz to 250 kHz Additional ON/OFF enables/disables constant frequency offset
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.rfSettings.dtx.sing.foffset.clone()
Subgroups