LowEnergy

SCPI Commands

CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy:LE1M
CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy:LRANge
CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy:LE2M
class LowEnergy[source]

LowEnergy commands group definition. 3 total commands, 0 Sub-groups, 3 group commands

get_le_1_m()float[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy[:LE1M]
value: float or bool = driver.configure.rfSettings.dtx.sing.mindex.standard.lowEnergy.get_le_1_m()
Specifies the modulation corruption of the signal. Modulation index of 0.5 means no corruption.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE direct test mode:

Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE connection tests (normal mode) :

Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE test mode:

Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.

return

mod_index: numeric | ON | OFF Range: 0.4 to 0.6 Additional ON/OFF enables/disables modulation index.

get_le_2_m()float[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy:LE2M
value: float or bool = driver.configure.rfSettings.dtx.sing.mindex.standard.lowEnergy.get_le_2_m()
Specifies the modulation corruption of the signal. Modulation index of 0.5 means no corruption.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE direct test mode:

Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE connection tests (normal mode) :

Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE test mode:

Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.

return

mod_index: numeric | ON | OFF Range: 0.4 to 0.6 Additional ON/OFF enables/disables modulation index.

get_lrange()float[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy:LRANge
value: float or bool = driver.configure.rfSettings.dtx.sing.mindex.standard.lowEnergy.get_lrange()
Specifies the modulation corruption of the signal. Modulation index of 0.5 means no corruption.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE direct test mode:

Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE connection tests (normal mode) :

Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE test mode:

Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.

return

mod_index: numeric | ON | OFF Range: 0.4 to 0.6 Additional ON/OFF enables/disables modulation index.

set_le_1_m(mod_index: float)None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy[:LE1M]
driver.configure.rfSettings.dtx.sing.mindex.standard.lowEnergy.set_le_1_m(mod_index = 1.0)
Specifies the modulation corruption of the signal. Modulation index of 0.5 means no corruption.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE direct test mode:

Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE connection tests (normal mode) :

Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE test mode:

Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.

param mod_index

numeric | ON | OFF Range: 0.4 to 0.6 Additional ON/OFF enables/disables modulation index.

set_le_2_m(mod_index: float)None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy:LE2M
driver.configure.rfSettings.dtx.sing.mindex.standard.lowEnergy.set_le_2_m(mod_index = 1.0)
Specifies the modulation corruption of the signal. Modulation index of 0.5 means no corruption.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE direct test mode:

Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE connection tests (normal mode) :

Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE test mode:

Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.

param mod_index

numeric | ON | OFF Range: 0.4 to 0.6 Additional ON/OFF enables/disables modulation index.

set_lrange(mod_index: float)None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RFSettings:DTX:SING:MINDex:STANdard:LENergy:LRANge
driver.configure.rfSettings.dtx.sing.mindex.standard.lowEnergy.set_lrange(mod_index = 1.0)
Specifies the modulation corruption of the signal. Modulation index of 0.5 means no corruption.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE direct test mode:

Commands for test mode classic (..:BRATe..) , (..:EDRate..) and for LE direct test mode (..:LE1M..) , (..:LE2M..) , (.. :LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE connection tests (normal mode) :

Commands for uncoded LE 1M PHY (..:NMODe:LENergy:LE1M..) , LE 2M PHY (..:NMODe:LENergy:LE2M..) , and LE coded PHY (.. :NMODe:LENergy:LRANge..) are available.

INTRO_CMD_HELP: Refer also to the following commands:

  • LE test mode:

Commands for uncoded LE 1M PHY (..:TMODe:LENergy:LE1M..) , LE 2M PHY (..:TMODe:LENergy:LE2M..) , and LE coded PHY (.. :TMODe:LENergy:LRANge..) are available.

param mod_index

numeric | ON | OFF Range: 0.4 to 0.6 Additional ON/OFF enables/disables modulation index.