LowEnergy¶
SCPI Commands
CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LE1M
CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LE2M
CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LRANge
- class LowEnergy[source]
LowEnergy commands group definition. 3 total commands, 0 Sub-groups, 3 group commands
- get_le_1_m() → int[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LE1M value: int = driver.configure.rxQuality.packets.nmode.lowEnergy.get_le_1_m()
- Defines the number of packets to be measured per measurement cycle (statistics cycle) .
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- return
number_packets: numeric Range: 1 to 30E+3
- get_le_2_m() → int[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LE2M value: int = driver.configure.rxQuality.packets.nmode.lowEnergy.get_le_2_m()
- Defines the number of packets to be measured per measurement cycle (statistics cycle) .
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- return
number_packets: numeric Range: 1 to 30E+3
- get_lrange() → int[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LRANge value: int = driver.configure.rxQuality.packets.nmode.lowEnergy.get_lrange()
- Defines the number of packets to be measured per measurement cycle (statistics cycle) .
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- return
number_packets: numeric Range: 1 to 30E+3
- set_le_1_m(number_packets: int) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LE1M driver.configure.rxQuality.packets.nmode.lowEnergy.set_le_1_m(number_packets = 1)
- Defines the number of packets to be measured per measurement cycle (statistics cycle) .
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- param number_packets
numeric Range: 1 to 30E+3
- set_le_2_m(number_packets: int) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LE2M driver.configure.rxQuality.packets.nmode.lowEnergy.set_le_2_m(number_packets = 1)
- Defines the number of packets to be measured per measurement cycle (statistics cycle) .
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- param number_packets
numeric Range: 1 to 30E+3
- set_lrange(number_packets: int) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:PACKets:NMODe:LENergy:LRANge driver.configure.rxQuality.packets.nmode.lowEnergy.set_lrange(number_packets = 1)
- Defines the number of packets to be measured per measurement cycle (statistics cycle) .
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- param number_packets
numeric Range: 1 to 30E+3