LowEnergy¶
SCPI Commands
CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LE1M
CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LE2M
CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LRANge
- class LowEnergy[source]
LowEnergy commands group definition. 3 total commands, 0 Sub-groups, 3 group commands
- get_le_1_m() → float[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LE1M value: float or bool = driver.configure.rxQuality.search.limit.mper.nmode.lowEnergy.get_le_1_m()
- Specifies the upper PER limit for LE PER search measurements.
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- return
limit: numeric | ON | OFF Range: 0 % to 100 %, Unit: % Additional parameters: OFF | ON (disables the limit | enables the limit using the previous/default level)
- get_le_2_m() → float[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LE2M value: float or bool = driver.configure.rxQuality.search.limit.mper.nmode.lowEnergy.get_le_2_m()
- Specifies the upper PER limit for LE PER search measurements.
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- return
limit: numeric | ON | OFF Range: 0 % to 100 %, Unit: % Additional parameters: OFF | ON (disables the limit | enables the limit using the previous/default level)
- get_lrange() → float[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LRANge value: float or bool = driver.configure.rxQuality.search.limit.mper.nmode.lowEnergy.get_lrange()
- Specifies the upper PER limit for LE PER search measurements.
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- return
limit: numeric | ON | OFF Range: 0 % to 100 %, Unit: % Additional parameters: OFF | ON (disables the limit | enables the limit using the previous/default level)
- set_le_1_m(limit: float) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LE1M driver.configure.rxQuality.search.limit.mper.nmode.lowEnergy.set_le_1_m(limit = 1.0)
- Specifies the upper PER limit for LE PER search measurements.
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- param limit
numeric | ON | OFF Range: 0 % to 100 %, Unit: % Additional parameters: OFF | ON (disables the limit | enables the limit using the previous/default level)
- set_le_2_m(limit: float) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LE2M driver.configure.rxQuality.search.limit.mper.nmode.lowEnergy.set_le_2_m(limit = 1.0)
- Specifies the upper PER limit for LE PER search measurements.
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- param limit
numeric | ON | OFF Range: 0 % to 100 %, Unit: % Additional parameters: OFF | ON (disables the limit | enables the limit using the previous/default level)
- set_lrange(limit: float) → None[source]
# SCPI: CONFigure:BLUetooth:SIGNaling<Instance>:RXQuality:SEARch:LIMit:MPER:NMODe:LENergy:LRANge driver.configure.rxQuality.search.limit.mper.nmode.lowEnergy.set_lrange(limit = 1.0)
- Specifies the upper PER limit for LE PER search measurements.
INTRO_CMD_HELP: Refer also to the following commands:
LE direct test mode: Commands for uncoded LE 1M PHY (..:LE1M..) , LE 2M PHY (..:LE2M..) , and LE coded PHY (..:LRANge..) are available.
LE connection tests (normal mode) : Commands ..:NMODe:LENergy:.. are available.
LE test mode: Commands ..:TMODe:LENergy:.. are available.
- param limit
numeric | ON | OFF Range: 0 % to 100 %, Unit: % Additional parameters: OFF | ON (disables the limit | enables the limit using the previous/default level)