A2Nreference¶
SCPI Commands
READ:BLUetooth:SIGNaling<Instance>:RXQuality:IQCoherency:LENergy:LE1M:A2NReference
FETCh:BLUetooth:SIGNaling<Instance>:RXQuality:IQCoherency:LENergy:LE1M:A2NReference
CALCulate:BLUetooth:SIGNaling<Instance>:RXQuality:IQCoherency:LENergy:LE1M:A2NReference
- class A2Nreference[source]
A2Nreference commands group definition. 3 total commands, 0 Sub-groups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Trans_Packets: float: decimal No. of transmitted packets Range: 0 to 200E+6
Rec_Events: float: No parameter help available
Rec_Events_Val_Crc: float: No parameter help available
No_Valid_Iqp_Airs: enums.ResultStatus2: decimal No. of received valid IQ sample pairs
Valid_Iq_Pairs_Rec: enums.ResultStatus2: float Percentage of received valid IQ sample pairs related to all received IQ pairs
Mean_Phase_Diff: enums.ResultStatus2: No parameter help available
P_95_Mean_Ph_Diff: enums.ResultStatus2: No parameter help available
Rec_Events_Cnt: enums.ResultStatus2: decimal No. of received events
Pro_Events_Cnt: enums.ResultStatus2: decimal No. of processed events
Pro_Events_Val_Crc: enums.ResultStatus2: No parameter help available
Nof_Pos_Pha: enums.ResultStatus2: decimal No. of possible phase measurements determined by CTE length, slot length and number of antennas
- class ResultData[source]
Response structure. Fields:
Trans_Packets: int: decimal No. of transmitted packets Range: 0 to 200E+6
Rec_Events: float: No parameter help available
Rec_Events_Val_Crc: int: No parameter help available
No_Valid_Iqp_Airs: int: decimal No. of received valid IQ sample pairs
Valid_Iq_Pairs_Rec: float: float Percentage of received valid IQ sample pairs related to all received IQ pairs
Mean_Phase_Diff: float: No parameter help available
P_95_Mean_Ph_Diff: float: No parameter help available
Rec_Events_Cnt: int: decimal No. of received events
Pro_Events_Cnt: int: decimal No. of processed events
Pro_Events_Val_Crc: int: No parameter help available
Nof_Pos_Pha: int: decimal No. of possible phase measurements determined by CTE length, slot length and number of antennas
- calculate() → CalculateStruct[source]
# SCPI: CALCulate:BLUetooth:SIGNaling<Instance>:RXQuality:IQCoherency:LENergy:LE1M:A2NReference value: CalculateStruct = driver.rxQuality.iqCoherency.lowEnergy.le1M.a2Nreference.calculate()
Returns the results of IQ samples coherency RP(m) measurement for the specified non-reference antenna. Commands for uncoded LE 1M PHY (..:LE1M..) and LE 2M PHY (..:LE2M..) are available. Commands for the mandatory non-reference antenna (. ..:A1NReference) , and optional third (…:A2NReference) and fourth (…:A3NReference) antennas are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Use RsCmwBluetoothSig.reliability.last_value to read the updated reliability indicator.
- return
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() → ResultData[source]
# SCPI: FETCh:BLUetooth:SIGNaling<Instance>:RXQuality:IQCoherency:LENergy:LE1M:A2NReference value: ResultData = driver.rxQuality.iqCoherency.lowEnergy.le1M.a2Nreference.fetch()
Returns the results of IQ samples coherency RP(m) measurement for the specified non-reference antenna. Commands for uncoded LE 1M PHY (..:LE1M..) and LE 2M PHY (..:LE2M..) are available. Commands for the mandatory non-reference antenna (. ..:A1NReference) , and optional third (…:A2NReference) and fourth (…:A3NReference) antennas are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Use RsCmwBluetoothSig.reliability.last_value to read the updated reliability indicator.
- return
structure: for return value, see the help for ResultData structure arguments.
- read() → ResultData[source]
# SCPI: READ:BLUetooth:SIGNaling<Instance>:RXQuality:IQCoherency:LENergy:LE1M:A2NReference value: ResultData = driver.rxQuality.iqCoherency.lowEnergy.le1M.a2Nreference.read()
Returns the results of IQ samples coherency RP(m) measurement for the specified non-reference antenna. Commands for uncoded LE 1M PHY (..:LE1M..) and LE 2M PHY (..:LE2M..) are available. Commands for the mandatory non-reference antenna (. ..:A1NReference) , and optional third (…:A2NReference) and fourth (…:A3NReference) antennas are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
Use RsCmwBluetoothSig.reliability.last_value to read the updated reliability indicator.
- return
structure: for return value, see the help for ResultData structure arguments.