Le2M¶
SCPI Commands
READ:BLUetooth:SIGNaling<Instance>:RXQuality:IQDRange:ANTMeanamp:LENergy:LE2M
FETCh:BLUetooth:SIGNaling<Instance>:RXQuality:IQDRange:ANTMeanamp:LENergy:LE2M
CALCulate:BLUetooth:SIGNaling<Instance>:RXQuality:IQDRange:ANTMeanamp:LENergy:LE2M
- class Le2M[source]
Le2M commands group definition. 3 total commands, 0 Sub-groups, 3 group commands
- class CalculateStruct[source]
Response structure. Fields:
Reliability: int: decimal See ‘Reliability Indicator’
Ant_3_Minus_2: float: float MeanAmplitudeANT3 - MeanAmplitudeANT2 Range: -256 to 128
Ant_2_Minus_Ref: float: float MeanAmplitudeANT2 - MeanAmplitudeANT0 Range: -256 to 128
Ant_Ref_Minus_1: float: float MeanAmplitudeANT0 - MeanAmplitudeANT1 Range: -256 to 128
- class ResultData[source]
Response structure. Fields:
Reliability: int: decimal See ‘Reliability Indicator’
Ant_3_Minus_2: float: float MeanAmplitudeANT3 - MeanAmplitudeANT2 Range: -256 to 128
Ant_2_Minus_Ref: float: float MeanAmplitudeANT2 - MeanAmplitudeANT0 Range: -256 to 128
Ant_Ref_Minus_1: float: float MeanAmplitudeANT0 - MeanAmplitudeANT1 Range: -256 to 128
- calculate() → CalculateStruct[source]
# SCPI: CALCulate:BLUetooth:SIGNaling<Instance>:RXQuality:IQDRange:ANTMeanamp:LENergy:LE2M value: CalculateStruct = driver.rxQuality.iqDrange.antMeanAmp.lowEnergy.le2M.calculate()
Returns the results of IQ dynamic range Rx measurement for the antenna mean amplitude differences. Commands for uncoded LE 1M PHY (..:LE1M..) and LE 2M PHY (..:LE2M..) are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for CalculateStruct structure arguments.
- fetch() → ResultData[source]
# SCPI: FETCh:BLUetooth:SIGNaling<Instance>:RXQuality:IQDRange:ANTMeanamp:LENergy:LE2M value: ResultData = driver.rxQuality.iqDrange.antMeanAmp.lowEnergy.le2M.fetch()
Returns the results of IQ dynamic range Rx measurement for the antenna mean amplitude differences. Commands for uncoded LE 1M PHY (..:LE1M..) and LE 2M PHY (..:LE2M..) are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for ResultData structure arguments.
- read() → ResultData[source]
# SCPI: READ:BLUetooth:SIGNaling<Instance>:RXQuality:IQDRange:ANTMeanamp:LENergy:LE2M value: ResultData = driver.rxQuality.iqDrange.antMeanAmp.lowEnergy.le2M.read()
Returns the results of IQ dynamic range Rx measurement for the antenna mean amplitude differences. Commands for uncoded LE 1M PHY (..:LE1M..) and LE 2M PHY (..:LE2M..) are available. The values described below are returned by FETCh and READ commands. CALCulate commands return limit check results instead, one value for each result listed below.
- return
structure: for return value, see the help for ResultData structure arguments.